• 40 years of experience in special diets for laboratory animals
  • Optimal quality
en
Menu

Laboratory equipment

Capnotrue® AMP Mainstream CO2/SPO2 Monitors (for rats and large animals)

Only available in Belgium

Features

Advanced an reliable capnograph and puls oximeter combined in a single monitor.

  • Mainstream CO² measurement with the IRMA™ CO²analyzer
  • Warm-up time: < 10s full  specification
  • Direct measurement without time delay
  • Small, light-weight and shock-resistant: the IRMA™ CO² analyzer weighs less than 30 g
  • Adult/paediatric, infant/neonatal, and a for rat  modified IRMA™ airway adapter
  • Plug and measure technology
  • IRMA™ airway adapters with non-condensing light transmissionXTP™window
  • No occlusion by water or mucus possible
  • Full range of key technology accessories
  • Maintenance and calibration-free technology
  • Wide range of high-quality SpO2  sensors

Dilivery Package

  • Mainstream device
  • IRMA™ CO² analyser
  • Reusable SpO² sensor
  • CapnoTrue® power supply (EU and UK plug)
  • USB data cable
  • IRMA™airway adapter (adult/paediatric)
  • Instruction manual
  • 1 Li-ion rechargeable battery
  • PC software
  • 4 batteries (AA)

The CapnoTrue AMp Mainstream Monitor can be used in combination with the uno MiCroVenTiLaTor - uMV-03.

The CapnoTrue AMP and ASP - CO²/SpO² monitors including the IRMA™ CO² analyzer, ISA™CO² analyzer and SoftCap Sensors are classified and certified as class IIb   products.

 

Technical spcifications

Swipe left and right to see the entire table.
Measurement range EtCO² and FICO² 0-15%
SpO² 0-100%
Respiration rate 0-150 breaths/min
Pulse rate 20-300 beats/min
Accuracy EtCO² and FICO² +/- (0.2 vol % + 2% of reading)
+/- (0.3 vol % + 4% of reading) incl. interfering gas
SpO² +/- 2% (70-100%)
Respiration rate +/-1 digit at 60 breaths/min
Pulse rate +/- ditit (uop to 100/min) or +/- 1% (<100/min)
Display
Characteristics Active OLED colour graphic display, 262.000 colours, 240 x 320 dots
Displayed data End-tidal CO²and inspired CO² in vol %, kPa or mmHg, oxygen saturation, respirationrate, pulse rate, capnogram, plethysmogram and short term trend
Indicators Signal strength and signal quality, pulse amplitude, battery status, alarm mut, pulse tone mute, neonatal mode, time
Trend information
Long term trend up to 400 hours
Short term trend 15 min/1h/6h
Language versions
  Englisch (additional language versions on request)
Environmental conditions
Operation 0 - 50°C, 15 - 95% r.H. (non-condensing), 60 - 120 kPa (excl. Li-ion battery)
Storage -30 - 70°C, 10 - 95% r.H. (non- condensing),60 - 120 kPa (excl. Li-ion battery)
Classification
Product class IIb (in accordance with MDD 93 / 42 / EEC)
Safety Class of protection II / type BF
Construction IPX1
Standards EN 60601-1:2006, EN 60601-1-1:2001, EN 60601-1-2:2007, EN 60601-1-8:2004, DIN EN 60529, EN ISO 21647:2004,EN ISO 9919:2005
Miscellaneous
Dimensions (LxWxD) 150 mm x 75 mm x 35 mm
Weight <400 g (complete divice with batteries)
Power supply 90-260 VAC/6 VDC, 50-60 Hz, 4 AA batteries, 2.5 Ah Li-ion battery
Battery capacity up to 6 hours continuous operation
Communication interface USB 2.0

 

Ordering number

Swipe left and right to see the entire table.
180000170 Capnotrue AMP
180000172 Adjusted Probe to be used with Rats
180000173 Probe to be used with larger Animals