Features

High-performance and versatile anaesthetic agent monitoring.

  • Innovative micro-optic technology
  • Direct mainstream measurement without time delay
  • Compact, robust and ultra-light multigas analyzer
  • Warm-up time <20 seconds full  specification
  • Maintenance and calibration free technology
  • Self-explanatory, ergonimic operating function faci- litate intuitive operation
  • The colour information display, as well as the sim- ple information stucture, support quick decisions and a rapid user reaction in critical situations
  • Leading-edge power management with standard alkanline batteries or Li-Poly batteries or medical power supply (orcombined)
  • Two years warranty.

Dilivery Package

  • CapnoTure MG Multigas/SpO² Monitor
  • IRMA™ AX + Analyser
  • Instruction manual
  • 1 Li-ion rechargeable batterij
  • PC software
  • 4 batteries (AA)
  • IRMA™ Airway Adapter
  • Reusable SpO² sensor
  • Silicone protective cover
  • USB data cable
  • Manual

The CapnoTrue MG Monitor can be used in combination with the uno MiCroVenTiLaTor - uMV-03.

The CapnoTrue MG monitors including the IRMA™ CO2  analyzer, ISA™CO2  analyzer and SoftCap Sensors are classified and certified as class IIb  products.

 

Tecnical data

Swipe left and right to see the entire table.
Display    
  Numerical End-tital (et) CO²,-,N²O-and agent concentrations, inspired  (Fi) CO², N²O and agent concentrations (SpO²), Respiration Rate (RR), Pulse Rate (PR)
Parameters displayed Graphical Capnogram and trends of numerical data (15 min/l h./6 h.)
Indicators Signal Strength and signal quality, pulse amplitude, battery status, alarm mute, pulse tone mute, storage status, real-time mode, neonatal mode, time.
Characteristics Active OLED colour graphic display, 262.000 colours, 240 x 320 pixel (42 mm x 56 mm)
Capnography and anaesthetic agent measurement specifications
Measurement range etCO² and FICO² 0-15%
FIN²O 0-100%
Hal, Iso, Enf 0-8%
Sev 0-10%
Des 0-22%
Respiration rate 0-150 l/min
Accuracy EtCO² en FICO² +/- (0,2 vol % + 2% of reading)
+/- (0,3 vol % + 4% of reading) incl. interfering gasses
N²O +/- (2 vol % + 2% of reading)
+/- (3 vol % + 5% of reading) incl. interfering gasses
Hal/Iso/Enf/Sev/Des +/- (0,15 vol % + 5% of reading)
+/- (0,2 vol % + 10% of reading) incl. interfering gasses
Ademhalingsvolume +/- 1
Warm-up time <20 seconds full specification
Pulse Oximetry Specifications
Measurement Range SpO²
Pulse Rate
1 -100%
20-300 l/min
Accuracy SpO²
Pulse Rate
+/- 2% (70 bis 100%)
+/- 1 digit (up to 100 l/min) or +/- 1% (> 100 l/min)
Trend Information
Long term trend up to 150 hours
Short term trend 15 min/l u./6h
Alarms
Limits Adjustable limits for all numerical parameters except for MaC
Alerts Audible and visual alarms (comlies with EN60601-1-8)
Storing Data
Communication interface USB 2.0
Data memory capacity up to 150 hours
Real-time-mode Visualisation and storage of numerical parameters on a computer every 4 seconds
Computer Software CapnoTrue® MG PC Software for data download and real-time mode
Power supply
Battery Working time with full functionalilty approx. 4,5 hours, 4 alkalline batteries (AA/LR6/AM3/MN1500/Mignon), 1,5V
Li-Poly battery Working time with full funtionalilty approx. 7 hours, Li-Poly battery, Model No CT-2500, 3,7V, 2500 mAh, charging time approx 5 hours
AC power supply Model No. FW 7660M/06, medical power supply with option for country-specific input plug, input: 100-240V AC/50-60Hz / 250 mA, output: 6 VDC/1,4A
Specifications Environmental conditions
Operation 10 - 40°C, 15 -95% r.H. (non-condensing), 60 - 120 kPa (excl. Li-poly battery)
Storage -20 -70°C, 10 - 95% r.H. (non-condensing), 60 - 120 kPa (excl. Li-poly battery)
Classification
Product class IIb (in accordance with MDD 93 / 42 /EEC)
Safety Class of protection II / type BF - Type and degree of protection against shock
Construction IPX1 (with silicone protective cover)
Normen EN 60601-1:2006, IEC 60601-1-1:2001, IEC 60601-1-4-2000; IEC 60601-1-8:2006: ISO 21647:2004:ISO 9919:2005; ISO 5356-1:2004; DIN EN 1789:2007, EN846:1996
Miscellaneous
Dimensions 150 mm x 75 mm x 35 mm
Weight < 400 g (complete device with batteries)

 

With its ultra-compct, light and easy to handle design, the Capnotrue®MG is the perfect felxible and mobile monitor for identifying and quantifying the five most important anaesthetic agents as well as other gases and parameters:

  • Halothane, Isoflurane, Enflurane, Sevoflurane and Desflurane
  • N²O
  • etCO², FICO²
  • Oxygen saturation
  • Respiration and Pulse Rate

By direct measurement in the mainstream, there is no time delay in the measuring data.

Reliable automatic agent identification and quantification
The IRMA AX+ Analyzer is equipped with state-of-the-art NDIR technology with up to 9-channel gas type analysis in the 4-10µm range and offers reliable agent identification and quantification even in gas mixtures. It weighs less than 25 g.

Probes to be used with rat

Probes to be used with large animals

Ordering number

Swipe left and right to see the entire table.
180000171 Capnotrue MG (Multigas)