Only available in Belgium
I, II, III and IV series double cannula systems for acute and chronic intracranial drug administration in animal experiment.
Application
Double cannula system is used for bilateral implantation, suitable for injecting one or two drugs into two different brain regions.
First, you have to decide the targeted brain region for drug administration and then set target values for C,C.C,G1 and G2 (the targeted value can’t be more than the default values or the maximum values of the total length, please refer to * for detailed information). We can custom the length according to the list below:
* C value: the maximal custom length is 13.7mm for I and III series, 20.0mm for II series and 10.0mm for IV series)
* C.C value: the custom range is 0.5mm ~3.0mm (the minimum incremental unit is ±0.1mm)
* G1: the maximal custom length is 5.5mm for I series, 3.5mm forII series, 7.5mm for III series and 4.0mm for IV series.
* G2: the maximal custom length is 3.0 mm for I series, 4.0mm for II series, 5.5mm for III series and 4.0mm for IV series.
Matching | C.C. | Guiding cannula | Dummy cannula | Injector | Cap | Fixing screw |
Class I |
0,5 mm | 62U021 | 62U121 | 62U221 | 62U523 | 62U521 |
0,6 mm | 62U022 | 62U122 | 62U222 | |||
0,8 mm | 62U023 | 62U123 | 62U223 | |||
1,0 mm | 62U024 | 62U124 | 62U224 | |||
1,2 mm | 62U025 | 62U125 | 62U225 | |||
1,3 mm | 62U026 | 62U126 | 62U226 | |||
1,4 mm | 62U027 | 62U127 | 62U227 | |||
1,5 mm | 62U028 | 62U128 | 62U228 | |||
1,6 mm | 62U029 | 62U129 | 62U229 | |||
1,8 mm | 62U030 | 62U130 | 62U230 | |||
2,0 mm | 62U031 | 62U131 | 62U231 | |||
Plastic base of Guide cannula Diameter E = 5.0mm |
2,2 mm | 62U032 | 62U132 | 62U232 | 62U524 | 62U522 |
2,4 mm | 62U033 | 62U133 | 62U233 | |||
2,6 mm | 62U034 | 62U134 | 62U234 | |||
2,7 mm | 62U035 | 62U135 | 62U235 | |||
3,0 mm | 62U036 | 62U136 | 62U236 |
Matching | C.C. | Guide cannula | Dummy cannula | Injector | Cap | Fixing screw |
Class II |
0,8 mm | 62U037 | 62U137 | 62U237 | 62U523 | 62U521 |
1,0 mm | 62U038 | 62U138 | 62U238 | |||
1,2 mm | 62U039 | 62U139 | 62U239 | |||
1,3 mm | 62U040 | 62U140 | 62U240 | |||
1,4 mm | 62U041 | 62U141 | 62U241 | |||
1,5 mm | 62U042 | 62U142 | 62U242 | |||
1,8 mm | 62U043 | 62U143 | 62U243 | |||
Plastic base of Guide Cannula Diameter E = 5.0mm |
2,0 mm | 62U044 | 62U144 | 62U244 | 62U524 | 62U522 |
2,2 mm | 62U045 | 62U145 | 62U245 | |||
2,4 mm | 62U046 | 62U146 | 62U246 | |||
2,5 mm | 62U047 | 62U147 | 62U247 | |||
2,8 mm | 62U048 | 62U148 | 62U248 | |||
3,0 mm | 62U049 | 62U149 | 62U249 |
Matching | C.C. | Guide cannula | Dummy cannula | Injector | Cap | Fixing screw |
Class III |
0,5 mm | 62U050 | 62U121 | 62U221 | 62U523 | 62U521 |
0,6 mm | 62U051 | 62U122 | 62U222 | |||
0,8 mm | 62U052 | 62U123 | 62U223 | |||
1,0 mm | 62U053 | 62U124 | 62U224 | |||
1,2 mm | 62U054 | 62U125 | 62U225 | |||
1,3 mm | 62U055 | 62U126 | 62U226 | |||
1,4 mm | 62U056 | 62U127 | 62U227 | |||
1,5 mm | 62U057 | 62U128 | 62U228 | |||
1,6 mm | 62U058 | 62U129 | 62U229 | |||
1,8 mm | 62U059 | 62U130 | 62U230 | |||
2,0 mm | 62U060 | 62U131 | 62U231 |
Matching | C.C. | Guide cannula | Dummy cannula | Injector | Cap | Fixing screw |
Class IV |
0,5 mm | 62U061 | 62U161 | 62U261 | 62U523 | 62U521 |
0,6 mm | 62U062 | 62U162 | 62U262 | |||
0,8 mm | 62U063 | 62U163 | 62U263 | |||
1,0 mm | 62U064 | 62U164 | 62U264 | |||
1,2 mm | 62U065 | 62U165 | 62U265 | |||
1,3 mm | 62U066 | 62U166 | 62U266 | |||
1,4 mm | 62U067 | 62U167 | 62U267 | |||
1,5 mm | 62U068 | 62U168 | 62U268 | |||
1,6 mm | 62U069 | 62U169 | 62U269 | |||
1,8 mm | 62U070 | 62U170 | 62U260 | |||
2,0 mm | 62U071 | 62U171 | 62U261 |
Note: The difference between Class I and Class III is the height size of the Double Guide Cannula, the former is 7.8mm and the latter is 5.5mm, and the Class III is specially designed for mice.